Sulfate Test Kit (0-200ppm)

 Sulfate Test Kit (0-200ppm)

Easily measure sulfate in water and process liquids. Monitor mineral levels in drinking water, groundwater, water treatment and industrial systems.

  • Results within minutes
  • High repeatability
Providing details like intended use, delivery location, packaging preference, and quantity will help us offer you faster and more accurate pricing.
Product Code: 238
Barcode: 8680131852383
Last update: 25 Ekim 2026 , Pazar

Testonic® Sulfate Test Kit (Turbidimetric) is designed for the rapid and convenient determination of sulfate (SO42−) ions in water samples. It helps evaluate mineral content, monitor water treatment performance, and support routine water quality control.

The kit is suitable for drinking and utility water, well water, boiler systems, cooling towers, textile operations, industrial processes, and wastewater monitoring. Its turbidimetric method based on turbidity formation allows testing without expensive laboratory instruments. After adding the test reagents, the developed turbidity is compared with the supplied reference scale to determine the sulfate concentration in approximately 5 minutes.

It provides a practical solution for comparing water sources, monitoring the mineral content of process water, and assessing the potential for sulfate-related deposits.

Measuring Range 0 – 200 ppm
Test Time Approx. 5 Minutes
Test Capacity Approx. 50 Tests

Why Is Sulfate Testing Important?

Sulfate is a dissolved ion found in natural waters and industrial water systems. Under certain conditions, sulfate may combine with calcium to form calcium sulfate deposits. Such deposits can affect the efficiency of pipes, boilers, and heat transfer equipment. Regular sulfate testing helps monitor the mineral composition of water and evaluate water treatment performance.

Sulfate Testing in 3 Simple Steps

  1. Prepare the Sample: Fill the graduated test vial with the water sample to the level specified in the instructions.
  2. Perform the Test: Add the sulfate test reagents in the specified sequence and allow turbidity to develop.
  3. Read the Result: Compare the developed turbidity with the supplied reference scale to determine the sulfate level.

Package Contents

  • Sulfate test reagents (2 solutions)
  • 5/10 mL graduated test vial
  • Visual comparison scale
  • Instruction manual

Testonic® Sulfate Test Kit (Turbidimetric) provides a practical visual turbidimetric method for determining sulfate ions (SO42−) in water samples. It can be used for sulfate monitoring in drinking and utility water, well water, boiler and cooling systems, industrial processes, and wastewater applications.

Results are determined by comparing the turbidity developed in the sample with the supplied reference scale. This allows on-site testing without a spectrophotometer or other laboratory instruments. Results obtained in approximately 5 minutes help monitor sulfate content and evaluate water treatment applications.

Measuring Range0 – 200 ppm SO42−
Analytical MethodTurbidimetric
Test TimeApprox. 5 minutes
Test CapacityApprox. 50 tests

Analytical Principle

Turbidimetric sulfate analysis is based on the formation of finely dispersed insoluble particles associated with sulfate ions in the sample. These particles produce turbidity that can be used to evaluate sulfate concentration under controlled testing conditions.

With this kit, the developed turbidity is compared visually with a reference scale. This allows sulfate testing to be performed without laboratory instruments in field and routine water quality applications.

Why Measure Sulfate?

Sulfate may occur naturally in water through the dissolution of rocks and minerals. It can also enter water through industrial activities. Sulfate is an important parameter when evaluating the mineral composition of water.

Under certain conditions, calcium sulfate deposits may form in waters containing calcium. Sulfate monitoring therefore provides useful information for boiler systems, cooling towers, and other industrial water applications.

  • Drinking and utility water: Monitoring the sulfate content of water.
  • Well and groundwater: Evaluating the mineral composition of water sources.
  • Steam boilers: Monitoring sulfate levels in boiler feedwater.
  • Cooling towers: Tracking sulfate concentration and mineral deposit risks.
  • Textile operations: Checking sulfate levels in process and washing water.
  • Industrial processes: Evaluating sulfate concentrations in process water.
  • Wastewater: Routine monitoring of changes in sulfate concentration.

How to Perform the Test

1. Prepare the Sample

Fill the clean graduated test vial with the water sample to the level specified in the instruction manual.

2. Add the Reagents

Apply the sulfate test reagents in the specified sequence and amounts, then allow the turbidity to develop.

3. Read the Result

Compare the developed turbidity with the reference scale to determine the sulfate concentration.

Technical Specifications

Measured parameter Sulfate (SO42−)
Analytical method Turbidimetric, visual comparison
Measuring range 0 – 200 ppm SO42−
Result reading Visual turbidity comparison with a reference scale
Test time Approx. 5 minutes
Test capacity Approx. 50 tests
Kit components 2 test solutions, graduated vial, reference scale, and instruction manual
Storage temperature 8 – 24 °C

Interpreting the Results

The turbidity developed during the test is compared with the kit's reference scale. The closest matching scale value is read as the sulfate concentration. Results are expressed in ppm SO42−.

In dilute aqueous solutions, 1 ppm sulfate is approximately equivalent to 1 mg/L SO42−. For example, a result of 100 ppm corresponds to approximately 100 mg/L sulfate.

The suitability of a measured concentration depends on the intended use of the water and the water quality targets established for the system. Recording results over time helps identify changes in source water and process conditions.

Related Water Quality Parameters

Parameter What It Indicates
Sulfate Sulfate ion concentration in water
Total Hardness Hardness caused by calcium and magnesium
Chloride Chloride ion concentration in water
pH Acidity and alkalinity condition of water
Silica Risk of silica-related mineral deposits

Important Usage Notes

  • Use a clean test vial for each measurement.
  • Add the reagents in the sequence and amounts specified in the instruction manual.
  • Perform visual comparisons under consistent and suitable lighting.
  • Follow the same test procedure when comparing results over time.
  • Keep reagent containers closed and store them under the specified conditions.

Frequently Asked Questions

What does the sulfate test kit measure?

It measures the concentration of sulfate ions (SO42−) in water samples. Results are expressed in ppm.

What is a turbidimetric method?

It is an analytical method that uses turbidity developed in a sample for measurement. This kit uses a reference scale for visual comparison.

Why is sulfate present in water?

Sulfate may enter water through the dissolution of natural rocks and minerals. It can also originate from industrial processes and other water sources.

Can sulfate contribute to mineral scale?

Yes. Under suitable conditions, sulfate may contribute to calcium sulfate deposits in waters containing calcium. Sulfate monitoring is therefore relevant to certain industrial water systems.

Are sulfate and sulfite the same?

No. Sulfate (SO42−) and sulfite (SO32−) are different chemical ions. This kit is designed for sulfate measurement.

Is a laboratory instrument required?

No. The result is determined by visually comparing the developed turbidity with the reference scale supplied with the kit.

How many tests can be performed with one kit?

The kit provides approximately 50 tests. Actual capacity depends on the test procedure and reagent consumption.

For Drinking Water Production Facilities

It helps assess the safety and health criteria of water by determining whether sulfate levels in drinking water meet regulatory standards.

For Textile Finishing and Dyeing Businesses

Determines the sulphate content of water in textile dyeing processes.

Pollution Monitoring and Water Quality Testing for Environmental and Wastewater Management

It contributes to monitoring water quality and controlling environmental pollution by determining the presence of sulfate ions in natural water resources and wastewater.

Test and Process Control Kits for Textile Finishing and Dyeing Mills

Monitors sulfate in process water, salt solutions or auxiliary samples, helping assess water quality and bath salinity-related risks.

Technical Documents

No technical document has been added for this product yet.
Related Posts

Related News

Technical Support and Product Consulting

You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.

You can ask us about the product.

Colin Chemical Industry Inc.
We have been offering specific solutions for your scientific preferences for 26 years.

İkitelli OSB Mutsan Sanayi Sitesi M10 Blok No:3 Başakşehir İSTANBUL


© 2026 Colin Kimya San. ve Tic. A.Ş. All Rights Reserved. 216.73.216.104