Testonic® Polyaluminium Chloride (PAC) Test Kit is designed for fast and convenient monitoring of polyaluminium chloride (PAC)-related residues in water treatment and textile processes. It provides visual color-based assessment within a 0.05–0.5 ppm PAC measurement range.
The kit is particularly suitable for monitoring PAC residues in liquid salt (NaCl), process water, dye baths, and treated water used in textile dyehouses. Its simple, instrument-free procedure provides results in approximately 5 minutes.
Why Is PAC Residue Monitoring Important?
Polyaluminium chloride is a coagulant used in water treatment and various industrial processes. PAC-related aluminium residues carried into process water or liquid salt may, under certain conditions, interact with dyes and auxiliary chemicals and contribute to staining, shade variation, and uneven dyeing. Regular testing makes it easier to investigate potential residue sources before production.
PAC Testing in 3 Easy Steps
- Prepare the Sample: Fill the graduated test tube with the specified volume of water or suitable liquid salt sample according to the instructions.
- Perform the Test: Add the kit solutions in the sequence specified in the user manual and prepare the sample.
- Read the Result: Compare the developed color with the reference color scale to evaluate the PAC level.
Kit Contents
- PAC Test Solution A
- PAC Test Solution B
- Graduated Test Tube
- Color Scale
- Instructions for Use
Testonic® Polyaluminium Chloride (PAC) Test Kit
Testonic® Polyaluminium Chloride (PAC) Test Kit is designed for rapid monitoring of PAC-related residues in textile and industrial water processes. Its color-based method allows low-level residue assessment without laboratory instruments.
With a 0.05–0.5 ppm PAC measurement range, the kit is particularly suitable for monitoring liquid salt, process water, dye baths, and treated water. It provides results in approximately 5 minutes, making it easier to monitor possible PAC carryover.
Analytical Principle
The test is based on a color reaction developed after preparing the PAC-containing sample with the kit reagents. The product's specific sample preparation and reagent application steps are used to obtain an analytical response from polymeric aluminium species.
The developed color is compared with the reference scale for semi-quantitative assessment within the 0.05–0.5 ppm PAC range.
Results should be interpreted according to the kit calibration for PAC. Other aluminium species may also influence the analytical response, so the test should not be regarded as independent confirmation of PAC molecular identity.
Why Is PAC Residue Monitoring Important?
Polyaluminium chloride is a coagulant used in water treatment processes. PAC-related aluminium species carried into process water or liquid salt may interact with dyes and textile auxiliaries under certain conditions.
Such interactions may contribute to staining, shade variation, precipitation, and uneven dyeing in some processes. Monitoring PAC residues makes it easier to investigate possible chemical sources and compare process water quality.
Applications
- Process water monitoring in textile dyehouses
- PAC screening in liquid salt and suitable NaCl solutions
- Coagulant-related residue monitoring in dye baths
- Industrial wastewater treatment outlets
- Brine monitoring in chlor-alkali processes
- Process water testing in paper and pulp production
- Water treatment and chemical quality control
How to Use
- Prepare the Sample: Fill the graduated test tube with the specified volume of water or suitable liquid salt sample according to the instructions.
- Perform the Test: Add the kit reagents in the sequence and quantities specified in the instructions to develop the color reaction.
- Evaluate the Result: Compare the developed color with the reference color scale to determine the PAC level.
Technical Specifications
| Product Name | Testonic® Polyaluminium Chloride (PAC) Test Kit |
| Target Parameter | PAC-related residues |
| Measurement Range | 0.05–0.5 ppm PAC |
| Sample Type | Process water, suitable liquid salt, and treated water samples |
| Test Method | Colorimetric reaction |
| Result Type | Semi-quantitative, color scale comparison |
| Analysis Time | Approximately 5 minutes |
| Test Capacity | Approximately 50 tests |
| Test Solutions | 2 bottles |
| Instrument Required | No |
| Storage Temperature | 8–24 °C |
Interpretation of Results
The developed sample color is compared with the reference color scale. Results are assessed as approximate values within the 0.05–0.5 ppm PAC range.
The measurement makes it possible to monitor the analytical response associated with PAC in the sample. Acceptability depends on the water characteristics, process conditions, and control criteria established by the facility.
A color change on the scale does not independently establish that a particular dyeing defect will occur. Results outside the measurement range may require suitable confirmatory analysis.
Analytical Interferences and Measurement Limitations
- Other aluminium species present in the sample may affect the colorimetric response.
- High salinity and ionic strength may influence the color reaction depending on sample conditions.
- Matrix suitability and result repeatability should be checked when testing saturated NaCl solutions.
- Sample color, turbidity, and pH may affect result interpretation.
- The stated measurement range is 0.05–0.5 ppm PAC.
- A suitable laboratory method should be used when definitive differentiation between aluminium species is required.
Related Process and Residue Parameters
Other parameters that may be monitored alongside PAC include:
- Aluminium: Separate assessment of aluminium species in water.
- pH: Monitoring coagulation and process conditions.
- Iron: Investigation of metal-related color and process problems.
- Salinity / Chloride: Monitoring liquid salt and process water characteristics.
- Anionic Polyelectrolyte: Monitoring other treatment chemical residues used in water treatment.
Important Use Notes
- Follow the instructions for sample volume and reagent addition sequence.
- Read the developed color within the time specified in the instructions.
- Apply appropriate matrix checks when testing highly saline samples.
- Use consistent analytical conditions when comparing samples.
- Evaluate relevant process parameters before changing dyeing recipes based on a single result.
Frequently Asked Questions
Test and Process Control Kits for Textile Finishing and Dyeing Mills
Monitors aluminum in water treatment, coagulant residuals or process water, helping evaluate precipitation, turbidity and surface residue risks.
Technical Documents
Related Posts
Related News
Technical Support and Product Consulting
You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.
You can ask us about the product.