Testonic® Ozone Test Kit is designed for easy measurement of dissolved ozone (O₃) in water. It provides a practical way to monitor ozone levels in ozonated water, ozone generator systems, and water treatment applications.
With a measurement range of 0.0–1.0 mg/L O₃, the kit uses a simple drop-counting method to provide results in approximately 5 minutes without electronic instruments. Easily monitor residual ozone concentrations after water ozonation.
Ozone Testing in 3 Simple Steps
- Fill the test tube with the water volume specified in the instructions.
- Add the test solutions in the specified order while observing the color change and counting the measurement drops.
- Determine the ozone result using the drop-counting procedure described in the instructions.
Who Can Use It?
Ozone generator users, water treatment and disinfection operators, food processing facilities, aquaculture operators, and anyone monitoring residual ozone levels in ozonated water.
Package Contents
- Solution A and Solution B
- Test tube
- Instructions for use
Note: Since dissolved ozone gradually decomposes in water, testing should be performed promptly after sample collection.
Ozone Test Kit – Dissolved Ozone (O₃) Measurement in Water
Testonic® Ozone Test Kit is a practical, instrument-free testing solution designed to determine dissolved ozone concentrations in ozonated water.
With a measurement range of 0.0–1.0 mg/L O₃, the kit can be used to monitor ozone generators, ozonated water preparation systems, and water disinfection applications. Results are obtained in approximately 5 minutes, making it convenient for on-site testing.
Analytical Principle
Ozone is a strong oxidizing agent that reacts with suitable color reagents, producing a measurable color change. Indigo-based ozone methods use the reduction in color intensity caused by the reaction with dissolved ozone.
The Testonic® Ozone Test Kit uses a color reaction and drop-counting evaluation to determine the dissolved ozone concentration in mg/L O₃. Results are calculated according to the procedure supplied with the kit.
Why Is Ozone Testing Important?
Ozone is a powerful oxidizing agent used in water treatment and disinfection. However, dissolved ozone is unstable and gradually decomposes, reducing its concentration over time.
- Ozone generators: Monitor dissolved ozone after ozone is introduced into water.
- Water disinfection: Check residual ozone levels following treatment.
- Food processing: Monitor ozonated water preparation and application processes.
- Water treatment: Compare operating conditions in ozonation systems.
Applications
- Ozone generators and ozonated water systems
- Drinking water and process water ozonation
- Food and beverage processing facilities
- Water treatment and disinfection systems
- Ozone applications in aquaculture
- Industrial processes using ozonated water
Testing in 3 Steps
Collect the specified water volume according to the instructions. Test the sample without unnecessary delay.
Add Solutions A and B in the specified order. Observe the color reaction and count the measurement drops.
Use the drop-counting procedure supplied with the kit to determine the dissolved ozone concentration in mg/L O₃.
Technical Specifications
| Specification | Description |
|---|---|
| Product | Ozone Test Kit |
| Measured parameter | Dissolved Ozone (O₃) |
| Measurement range | 0.0–1.0 mg/L O₃ |
| Test method | Color reaction with drop-counting evaluation |
| Result unit | mg/L O₃ (ppm) |
| Test time | Approximately 5 minutes |
| Test capacity | Approximately 50 tests |
| Equipment | No electronic measuring instrument required |
| Package contents | Solution A, Solution B, test tube, and instructions for use |
Result Interpretation
Test results indicate the dissolved ozone concentration in water, expressed as mg/L O₃. The conversion of measurement drop counts into ozone concentration must follow the procedure supplied with the kit.
| Test Result | Interpretation |
|---|---|
| No measurable ozone detected | Dissolved ozone was not detected at a level measurable by the kit. |
| Result within 0.0–1.0 mg/L | The result is within the specified measurement range. |
| Ozone levels above 1.0 mg/L | Outside the kit's measurement range. A suitable higher-range method is required. |
Important: Residual ozone concentration alone does not confirm disinfection effectiveness. Contact time and application conditions must also be considered.
Related Water Quality Parameters
| Parameter | Monitoring Purpose |
|---|---|
| Ozone (O₃) | Measures dissolved ozone concentration in water. |
| pH | Indicates the acidity or alkalinity of water. |
| Free Chlorine | Monitors free chlorine residuals in chlorinated systems. |
Practical Testing Notes
- Analyze samples promptly because dissolved ozone decomposes over time.
- Avoid excessive agitation and unnecessary sample transfers.
- Always use a clean test tube and the specified sample volume.
- Free chlorine and other oxidizing substances may interfere with certain ozone measurement methods.
- Use an appropriate alternative method for concentrations outside the specified range.
Frequently Asked Questions
Technical Documents
Related Posts
Related News
Technical Support and Product Consulting
You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.
You can ask us about the product.