Ultrasonic Cavitation Control Kit – Validation Type

Ultrasonic Cavitation Control Kit – Validation Type

Validation grade cavitation indicator for energy intensity. Vacuum-sealed technology for critical process validation (ISO 15883-5).

  • Ready-to-use formulation
  • Suitable for analytical laboratory use
  • Reproducible and reliable results
  • Suitable for calibration and reference use
  • Provides practical use in laboratory workflows
Providing details like intended use, delivery location, packaging preference, and quantity will help us offer you faster and more accurate pricing.
Product Code: 290
Barcode: 8680131852901
Last update: 4 Ekim 2026 , Pazar

Testonic® Sonic-Verify V is designed to measure the true power intensity of ultrasonic systems, going beyond standard routine checks. This "Validation Grade" kit scientifically proves that cavitation energy reaches every point, even in the most demanding cleaning processes, and that cleaning protocols meet critical validation criteria.


Product Highlights

  • Power Energy Intensity Measurement: Tests not only the presence of cavitation but also whether the "threshold energy level" required for cleaning has been exceeded.

  • Critical Validation: Verifies the minimum acoustic pressure required for surgical instruments and heavy industrial parts, aiming for full compliance with ISO 15883-5 standards.

  •  
  • Durable Formulation: High temperature (up to 70°C) and long cycle remaining stable throughout the process, providing reliable results until the end of challenging processes. gives.

  • Aero-V-Tech Vacuum Seal: The vacuum layer under the 2 ml aluminum crimp cap reduces external environmental effects to zero, allowing energy to be focused directly on the reaction.

  • Optical Transparency: With its transparent borosilicate glass structure, it allows you to observe the color change created by cavitation intensity in the clearest way.


Technical Specifications

Parameters

Details

Indicator Mechanism

High Energy Threshold Sonochemical Interaction

Reaction Characteristics

Difficult to Pass Through (Requires High Acoustic Pressure)

Operating Range

25 kHz - 45 kHz / 35°C - 70°C

Reaction Time

8 - 12 Minutes (Depending on Power Intensity)

Certification

Performance Compliant with ISO 15883-1 and ISO 15883-5


Critical Application Areas

  1. Central Sterilization Units (CSSD): Cleaning protocols of operating room sets validation.

  2. Heavy Industry and Automotive: Verification of oil removal performance of engine blocks, injectors and complex machine parts.

  3. Aerospace and Defense: Cleaning control of critical components requiring sensitive but intensive cavitation.

  4. Procurement and Quality Approval: Annual or semi-annual device performance validation reports.


Instructions for Use

  1. Preparation: Bring the device to operating temperature (e.g. 50-60°C) and Complete the degassing process.

  2. Strategic Placement: Perform a homogeneity test of the device by placing the Sonic-Verify V vial in the bottom, top, and middle sections of the basket (the most difficult-to-reach points).

  3. Operation: Run the device at full power for 10 minutes.

  4. Analysis: If the color change has completely changed from "Blue" to "Yellow", the power at that point The intensity is sufficient for critical cleaning.


Why Testonic™ Sonic-Verify V?

Every device makes a cavitation sound, but not every device "cleans". The Sonic-Verify V proves that your device not only works, but actually produces the energy to do the cleaning job. This means patient safety for hospitals and zero errors for industry.

Technical Documents

No technical document has been added for this product yet.
Related Posts

Related News

Technical Support and Product Consulting

You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.

You can ask us about the product.

Colin Chemical Industry Inc.
We have been offering specific solutions for your scientific preferences for 26 years.

İkitelli OSB Mutsan Sanayi Sitesi M10 Blok No:3 Başakşehir İSTANBUL


© 2026 Colin Kimya San. ve Tic. A.Ş. All Rights Reserved. 216.73.216.104