Cyanide Test Kit (CN⁻)

Cyanide Test Kit (CN⁻)

Easily check cyanide in water and industrial processes. Monitor wastewater treatment, metal plating operations and changes in process water.

  • Rapid result test format
  • Suitable for water quality monitoring
Providing details like intended use, delivery location, packaging preference, and quantity will help us offer you faster and more accurate pricing.
Product Code: 282
Barcode: 8680131852826
Last update: 27 Ekim 2026 , Salı

Testonic® Cyanide Test Kit (CN⁻) is designed for easy measurement of cyanide in water and suitable industrial liquid samples. It is particularly useful for cyanide monitoring in metal plating, surface treatment, wastewater treatment, and mining applications.

The color comparison method requires no electronic analytical instrument or complicated calculations. Simply apply the test reagents, compare the developed color with the reference scale, and read the cyanide concentration directly in ppm (mg/L).

0.3–5.0 ppm CN⁻ Cyanide level monitoring
Approx. 50 Tests Routine process monitoring
Results in 5 Minutes Easy color comparison

Why Should Cyanide Be Measured?

Cyanide compounds are used in certain metal plating, mining, and industrial manufacturing processes. Monitoring cyanide in process water and wastewater helps operators track production conditions and changes during wastewater treatment.

Who Uses It?

  • Metal plating and surface treatment facilities
  • Industrial wastewater treatment plants
  • Mining and metal processing operations
  • Process water testing and analytical laboratories

Easy Testing in 3 Steps

  1. Prepare the Sample: Fill the test tube with the sample volume specified in the instructions.
  2. Add the Reagents: Apply the test reagents in the specified order and quantities.
  3. Read the Result: Compare the developed color with the reference scale to determine the cyanide level in ppm (mg/L).

Kit Contents

  • Graduated test tube
  • Cyanide test reagents and solutions

Important: Samples containing cyanide can be hazardous. Testing must be performed by trained personnel using appropriate safety precautions.

Testonic® Cyanide Test Kit (CN⁻) is designed for fast and convenient measurement of cyanide levels in water and suitable industrial liquid samples through visual color comparison.

It is particularly useful for routine cyanide monitoring in metal plating, surface treatment, wastewater treatment, and mining operations. No electronic analytical instrument is required. Results are obtained in approximately 5 minutes by comparing the developed color with the reference scale.

Test Parameter
Cyanide (CN⁻)
Measuring Range
0.3–5.0 ppm (mg/L) CN⁻
Test Time
Approximately 5 minutes
Test Capacity
Approximately 50 tests

What Is It Used For?

Cyanide compounds are used in certain metal plating, mining, and industrial manufacturing processes. Cyanide from these operations may enter process water, rinsing baths, and industrial wastewater.

Regular cyanide measurements help operators monitor production conditions, compare water samples, and observe changes during wastewater treatment.

Main applications include:

  • Monitoring rinse water from metal plating operations
  • Comparing industrial wastewater samples before and after treatment
  • Cyanide monitoring in surface treatment and metal cleaning processes
  • Testing suitable liquid samples in mining facilities within the measuring range
  • Routine process water testing in industrial production

How Is the Test Performed?

The test is based on evaluating a color reaction associated with the cyanide concentration in the sample. Measurements are performed by following the procedure specified in the instructions.

1. Sample Collection
Fill the graduated test tube with the sample volume specified in the instructions.
2. Reagent Addition
Apply the test reagents in the specified order and quantities. Mix the sample as instructed.
3. Result Reading
Compare the developed color with the reference scale to determine the cyanide concentration in ppm (mg/L) CN⁻.

Technical Specifications

Test parameter Cyanide (CN⁻)
Test method Visual color comparison (colorimetric)
Measuring range 0.3–5.0 ppm (mg/L) CN⁻
Suitable samples Water and industrial liquids suitable for the test method
Instrument requirement No electronic analytical instrument required
Approximate test time 5 minutes
Approximate test capacity 50 tests
Storage conditions 8–24 °C, away from direct sunlight
Kit contents Graduated test tube, test reagents and solutions

Interpreting the Results

Visual color comparison provides an approximate determination of the cyanide level in the sample.

Measuring Range and Limitations
  • 0.3–5.0 ppm: The specified measuring range.
  • Below 0.3 ppm: Does not confirm the complete absence of cyanide.
  • Above 5.0 ppm: Requires evaluation using a suitable alternative analytical method.

Sample color, turbidity, and other chemical constituents may affect visual color comparison. Results should be evaluated according to the instructions.

Analytical Limitations and Safety

Cyanide can exist in free and metal-complexed forms in aqueous solutions. Free and total cyanide are different analytical parameters. Results from this kit must be interpreted according to the verified scope of the test method.

The kit is intended for routine process monitoring. It does not replace validated laboratory analysis required for official wastewater discharge compliance.

Safe Handling Samples containing cyanide may present serious toxic hazards. Do not add acids or other chemicals outside the kit instructions. Contact between cyanide solutions and acids can release highly toxic hydrogen cyanide (HCN) gas. Testing must be performed by trained personnel using appropriate protective equipment and ventilation. Used samples and reagents must be managed according to applicable hazardous waste procedures.

Frequently Asked Questions

Cyanide may be present in process water and wastewater from certain metal plating, surface treatment, mining, and chemical manufacturing operations.
Testing helps operators monitor cyanide in plating and rinsing waters, compare production stages, and observe wastewater treatment conditions.
Yes. Samples suitable for the method and measuring range can be compared to monitor changes in cyanide concentration.
No. Free cyanide generally refers to CN⁻ and HCN. Total cyanide analysis may include additional cyanide compounds, depending on the analytical method.
No. The cyanide concentration may be below the kit's measuring range. This does not confirm the complete absence of cyanide.
The sample is outside the kit's measuring range and should be evaluated using a suitable validated analytical method.
No. The kit is intended for routine process monitoring. Official compliance assessments require validated laboratory methods accepted under applicable regulations.
Results are available in approximately 5 minutes. Each kit provides approximately 50 tests.

Monitor cyanide levels in metal plating, wastewater treatment, and industrial processes with ease. Compare samples, track process changes, and simplify routine water testing.

Technical Documents

No technical document has been added for this product yet.
Related Posts

Related News

Technical Support and Product Consulting

You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.

You can ask us about the product.

Colin Chemical Industry Inc.
We have been offering specific solutions for your scientific preferences for 26 years.

İkitelli OSB Mutsan Sanayi Sitesi M10 Blok No:3 Başakşehir İSTANBUL


© 2026 Colin Kimya San. ve Tic. A.Ş. All Rights Reserved. 216.73.216.104