Testonic® Sonic-Verify S is a high-sensitivity test kit designed to monitor the daily performance of ultrasonic cleaning devices in medical, dental, and laboratory environments requiring precise cleaning. Thanks to its formulation sensitive to micro-cavitation energy, it can verify the cleaning power of your device down to the finest details. Confirms in seconds.
Key Advantages and Key Features
-
High Sensitivity: Provides reliable results even with sensitive devices operating at low energy levels.
-
V-Tech Vacuum Technology: The air inside the vial is evacuated during the production phase. This prevents acoustic damping and ensures the device's true cavitation power. Measured directly.
-
Instant Visual Verification: Without the need for complex laboratory analyses, "Pass/Fail" is indicated with a clear color change from green to yellow. It presents the result.
-
Leakproof Crimp Cap System: The special cap structure maintains the stability of the indicator liquid for 24 months and provides a complete barrier against external water.
Technical Specifications
|
Parameter |
Details |
|
Indicator Mechanism |
Special Sonochemical Interaction |
|
Standard Compliance |
Compliant with ISO 15883-5 Requirements |
|
Operating Range |
35 kHz - 120 kHz / 18°C - 70°C |
|
Reaction Time |
3 - 5 Minutes |
|
Package Contents |
20 Pieces |
Application Areas
-
Dental Clinics: Monitoring of surgical instrument and drill cleaning.
-
Laboratories: Verification of the cleanliness of delicate glassware and micropipette tips.
-
Optics and Jewelry: Daily efficiency control of ultrasonic baths.
-
Hospitals: Routine monitoring of low-volume devices in CSSD (Central Sterilization) units.
Instructions for Use
-
Preparation: Fill your ultrasonic bath and degas for 5-10 minutes.
-
Placement: Place one Sonic-Verify S vial in the center of the bath or in the corner of the basket.
-
Operation: Run the device on a standard flush cycle (or 5 Run for (minutes).
-
Evaluation: If the liquid in the vial has turned completely yellow, your device can be used safely. If it remains green, renew the solution or request a technical service check.
Why Testonic™ Sonic-Verify Solution?
Traditional foil tests are subjective and can leave residue. Testonic™ Sonic-Verify Solution proves, with its scientifically validated sonochemical method, that the pre-sterilization cleaning stage is completed without error.
Technical Documents
Related Posts
Related News
Technical Support and Product Consulting
You can use the form to find the most suitable chemical solution for your needs or to obtain detailed information about the technical specifications of our products.
Your requests are carefully reviewed and answered by Colin's expert team.
You can ask us about the product.